Eaton Unveils Modular Power Distribution Unit to Optimize Data Center Efficiency

by Lyle Smith
Eaton PP2 EX

The Eaton PDI PowerPak 2 EX PDU is a compact, flexible solution designed to meet the evolving demands of mid-range data centers.

Eaton has introduced the PDI PowerPak 2 EX (PP2 EX), a highly adaptable power distribution unit (PDU) engineered to meet the demands of medium, enterprise, and colocation data centers. Designed to handle power ratings from 300 to 625 kVA, the PP2 EX is tailored for environments where efficiency, flexibility, and compactness are paramount.

Eaton PP2 EX The unit addresses data centers’ growing complexity and spatial constraints by combining a modular design with a high-power density and advanced monitoring capabilities. These features allow operators to optimize their space while maintaining reliable and efficient power distribution for critical loads.

Eaton PDI PowerPak 2 EX PDU Features

The PP2 EX sets itself apart with its small footprint, making it one of the most compact PDUs available for mid-range applications. Its True Front Access (TFA) design minimizes the need for rear or side clearance, simplifying installation and maintenance while freeing up valuable floor space. Configurable breaker options, solid busbar connections, and universal top/bottom cable entry further enhance its adaptability to various data center layouts. In addition, the Eaton PDU’s compartmentalized electrical components improve safety and accessibility, while its modular construction ensures flexibility in system expansion and customization.

The PP2 EX is highlighted by its ultra-efficient transformer, designed to comply with DOE 2016 energy efficiency standards. The transformer utilizes 240°C-class insulation for extended operational life and features dual electrostatic shielding to attenuate high-frequency noise. This helps contribute to a reliable power system that minimizes energy loss while delivering optimal performance for mission-critical applications.

With multiple configuration options, the Eaton PP2 EX can handle single and dual output voltages, making it compatible with various operational requirements. Additionally, its oversized 200% neutral conductor supports high-current applications, improving reliability and safety.

Eaton has also outfitted the PP2 EX with WaveStar intelligent monitoring, which enables operators to track and manage critical loads in real time. The system provides granular visibility to the individual breaker level via an intuitive color touchscreen interface. For facilities requiring remote monitoring, the PDU supports integration with industry-standard protocols such as Modbus RTU, TCP/IP, BACnet, and SNMP.

Optional compatibility with Eaton’s Power Xpert Meter 3000 and PXR 25 smart circuit breakers allows for advanced analytics and configuration, making the Eaton PDI PowerPak 2 EX PDU a future-proof investment for data centers looking to enhance their operational insights.

Eaton PDI PowerPak 2 EX PDU Specifications
kVA Rating 300–625 kVA
Input Voltage
  • 50 Hz: 380V–690V
  • 60 Hz: 208V–600V
Output Voltage
  • Single: 50 Hz (380V–690V), 60 Hz (208V–600V)
  • Dual: Configurations include 208/120V–400/230V, 415/240V, and 480/277V
  • Multiple: Combinations of 208/120V, 400/230V, 415/240V, and 480/277V
Busbar Connection 200% Neutral
Certifications UL1062, UL1561, CSA Certified
Transformer Features
  • DOE2016-compliant TP1 transformers
  • Copper or aluminum windings
  • Dual electrostatic shield for noise attenuation
  • Oversized 200% neutral conductor
  • Common and transverse mode noise protection
  • UL-certified 240°C insulation system
Enclosure
  • NEMA1 standard, optional NEMA3R
  • True Front Access (TFA) design
  • Removable front, side, and rear panels
  • Flush-mounted door handle with integrated locks
Operating Conditions Temperature:

  •  0°C to 40°C (operating), -10°C to +40°C (storage)
  • Humidity: 0%-95%, non-condensing
  • Altitude: Up to 3,300 ft; contact Eaton for higher altitudes
  • Frequency Range: 50 Hz (47–53 Hz), 60 Hz (57–63 Hz)
Monitoring
  • WaveStar touchscreen LCD monitor
  • Optional Eaton PXM 3000 and PXR25 smart breakers
  • Communication: Modbus RTU, TCP/IP, BACnet, SNMP
  • nTrue RMS metering for kW, power factor, and THD
Power Protection
  • Lightning arrestor and surge suppressor
  • Dual transformer thermocouples
  • Manual dual-input system for maintenance without downtime

Eaton PDI PowerPak 2 EX PDU Design and Build

The PP2 EX features a rugged NEMA1 enclosure as the standard configuration, with an optional NEMA3R enclosure available for outdoor installations. The unit is also designed to operate in ambient temperatures ranging from 0°C to 40°C and can withstand relative humidity levels of up to 95%. Its ability to perform reliably at altitudes up to 3,300 feet further makes it well-suited for various operational environments.

Eaton PDI PowerPak 2 EX PDU Availability

The PDI PowerPak 2 EX is available now for purchase.

Eaton PDI PowerPak 2 EX PDU